130 research outputs found

    The bridge volcanic LIdar-BILLI: A review of data collection and processing techniques in the Italian most hazardous volcanic areas

    Get PDF
    Volcanologists have demonstrated that carbon dioxide (CO2) fluxes are precursors of volcanic eruptions. Controlling volcanic gases and, in particular, the CO2 flux, is technically challenging, but we can retrieve useful information from magmatic/geological process studies for the mitigation of volcanic hazards including air traffic security. Existing techniques used to probe volcanic gas fluxes have severe limitations such as the requirement of near-vent in situ measurements, which is unsafe for operators and deleterious for equipment. In order to overcome these limitations, a novel range-resolved DIAL-Lidar (Differential Absorption Light Detection and Ranging) has been developed as part of the ERC (European Research Council) Project "BRIDGE", for sensitive, remote, and safe real-time CO2 observations. Here, we report on data collection, processing techniques, and the most significant findings of the experimental campaigns carried out at the most hazardous volcanic areas in Italy: Pozzuoli Solfatara (Phlegraen Fields), Stromboli, and Mt. Etna. The BrIdge voLcanic LIdar-BILLI has successfully obtained accurate measurements of in-plume CO2 concentration and flux. In addition, wind velocity has also been retrieved. It has been shown that the measurements of CO2 concentration performed by BILLI are comparable to those carried out by volcanologists with other standard techniques, heralding a new era in the observation of long-term volcanic gases

    Impact of lesion delineation and intensity quantisation on the stability of texture features from lung nodules on ct: A reproducible study

    Get PDF
    Computer-assisted analysis of three-dimensional imaging data (radiomics) has received a lot of research attention as a possible means to improve the management of patients with lung cancer. Building robust predictive models for clinical decision making requires the imaging features to be stable enough to changes in the acquisition and extraction settings. Experimenting on 517 lung lesions from a cohort of 207 patients, we assessed the stability of 88 texture features from the following classes: first-order (13 features), Grey-level Co-Occurrence Matrix (24), Grey-level Difference Matrix (14), Grey-level Run-length Matrix (16), Grey-level Size Zone Matrix (16) and Neighbouring Grey-tone Difference Matrix (five). The analysis was based on a public dataset of lung nodules and open-access routines for feature extraction, which makes the study fully reproducible. Our results identified 30 features that had good or excellent stability relative to lesion delineation, 28 to intensity quantisation and 18 to both. We conclude that selecting the right set of imaging features is critical for building clinical predictive models, particularly when changes in lesion delineation and/or intensity quantisation are involved

    . New ground-based lidar enables volcanic CO2 flux measurements

    Get PDF
    There have been substantial advances in the ability to monitor the activity of hazardous volcanoes in recent decades. However, obtaining early warning of eruptions remains challenging, because the patterns and consequences of volcanic unrests are both complex and nonlinear. Measuring volcanic gases has long been a key aspect of volcano monitoring since these mobile fluids should reach the surface long before the magma. There has been considerable progress in methods for remote and in-situ gas sensing, but measuring the flux of volcanic CO2—the most reliable gas precursor to an eruption—has remained a challenge. Here we report on the first direct quantitative measurements of the volcanic CO2 flux using a newly designed differential absorption lidar (DIAL), which were performed at the restless Campi Flegrei volcano. We show that DIAL makes it possible to remotely obtain volcanic CO2 flux time series with a high temporal resolution (tens of minutes) and accuracy (<30%). The ability of this lidar to remotely sense volcanic CO2 represents a major step forward in volcano monitoring, and will contribute improved volcanic CO2 flux inventories. Our results also demonstrate the unusually strong degassing behavior of Campi Flegrei fumaroles in the current ongoing state of unrest

    Techniques for Effective Optical Noise Rejection in Amplitude-Modulated Laser Optical Radars for Underwater Three-Dimensional Imaging

    Get PDF
    Amplitude-modulated (AM) laser imaging is a promising technology for the production of accurate three-dimensional (3D) images of submerged scenes. The main challenge is that radiation scattered off water gives rise to a disturbing signal (optical noise) that degrades more and more the quality of 3D images for increasing turbidity. In this paper, we summarize a series of theoretical findings, that provide valuable hints for the development of experimental methods enabling a partial rejection of optical noise in underwater imaging systems. In order to assess the effectiveness of these methods, which range from modulation/demodulation to polarimetry, we carried out a series of experiments by using the laboratory prototype of an AM 3D imager ( = 405 nm) for marine archaeology surveys, in course of realization at the ENEA Artificial Vision Laboratory (Frascati, Rome). The obtained results confirm the validity of the proposed methods for optical noise rejection

    Equilibrium properties of a Josephson junction ladder with screening effects

    Full text link
    In this paper we calculate the ground state phase diagram of a Josephson Junction ladder when screening field effects are taken into account. We study the ground state configuration as a function of the external field, the penetration depth and the anisotropy of the ladder, using different approximations to the calculation of the induced fields. A series of tongues, characterized by the vortex density ω\omega, is obtained. The vortex density of the ground state, as a function of the external field, is a Devil's staircase, with a plateau for every rational value of ω\omega. The width of each of these steps depends strongly on the approximation made when calculating the inductance effect: if the self-inductance matrix is considered, the ω=0\omega=0 phase tends to occupy all the diagram as the penetration depth decreases. If, instead, the whole inductance matrix is considered, the width of any step tends to a non-zero value in the limit of very low penetration depth. We have also analyzed the stability of some simple metastable phases: screening fields are shown to enlarge their stability range.Comment: 16 pp, RevTex. Figures available upon request at [email protected] To be published in Physical Review B (01-Dec-96

    Radiation Tolerant 3D Laser Scanner for Structural Inspections in Nuclear Reactor Vessels and Fuel Storage Pools

    Get PDF
    Accurate and timely assessment of displacements and/or structural damages in nuclear reactor vessels' components is a key action in routine inspections for planning maintenance and repairs but also in emergency situations for mitigating consequences of nuclear incidents. Nevertheless, all these components are maintained underwater and reside in high-radiation fields thus imposing harsh operative conditions to inspection devices which must cope with effects such as Cerenkov radiation background, Total Ionizing Radiation (TID), and occlusions in the detectors' field of view. To date, ultrasonic techniques and video cameras are in use for inspection of components' integrity and with measurements of volumetric and surface crack opening displacements, respectively. The present work reports the realization of a radiation tolerant laser scanner and the results of tests in a nuclear research reactor vessel for acquisition of 3D models of critical components. The device, qualified for underwater operation and for withstanding up to 1 MGy of TID, is based on a 515 nm laser diode and a fast-scanning electro-optic unit. To evaluate performances in a significant but controlled environment, the device has been deployed in the vessel of a research reactor operated by ENEA in the Casaccia Research Centre in Rome (Italy). A 3D model of the fuel rods assembly through a cooling water column of 7 m has been acquired. The system includes proprietary postprocessing software that automatically recognizes components of interest and provides dimensional analysis. Possible application fields of the system stretch to dimensional analysis also in spent nuclear fuel storage pools

    Improving underwater imaging in an amplitude-modulated laser system with radio frequency control technique

    Get PDF
    We present the results of an experiment aimed to demonstrate the low-pass filter dependence of water backscattered power in an amplitude-modulated laser scanner for underwater 3D imaging. We also demonstrate that improvements in target imaging are obtained by allowing the device to operate in the stop-band region. A simple model is described to account for the physics underlying the effect and suggesting future experimental schemes based on demodulated detection techniques

    Improved understanding of self-sustained, sub-micrometric multi-composition surface Constantan wires interacting with H2 at high temperatures: experimental evidence of Anomalous Heat Effects

    Get PDF
    This article is an extension of what presented by our team at 17th International Conference on Cold Fusion, ICCF-17, in Daejon, Korea, in 2012 [1]. It documents the improvements on Constantan-related experiments, started in 2011, in order to study the feasibility of new Nickel based alloys that are able to absorb proper amounts of Hydrogen (H2) and/or Deuterium (D2) and that have, in principle, some possibility to generate anomalous thermal effects at temperatures &gt;100°C. The interest in Ni comes in part because there is the possibility to use also H2 instead of expensive D2. Moreover, cross-comparison of results using H2 instead of D2 can be made and could help the understanding of the phenomena involved (atomic, nuclear, super-chemical origin?) due to the use of such isotopes. Keywords: calorimeter, LENR, Nickel based alloys, sub-micrometric surface
    • …
    corecore